Know-How Portal from SMA Solar Technology AG — Photovoltaics, Solar Energy & Solar Technology
SMA America, LLC  ·  Tel. +1 916 625 0870
Photovoltaic Technology Overview
Overhead flat-lay of solar panel cells arranged in a neat grid, deep blue tones with clean charcoal borders, calm and technical mood

Solar energy sources, inverter technology, and installation know-how from SMA Solar Technology AG

Solar is Future gathers practical information on solar energy sources, photovoltaic technology, installation design, investment considerations, and recycling — built around the products and manufacturing experience of SMA Solar Technology AG, founded in 1981 in Niestetal, Germany.

Products Built on Inverter Leadership

SMA is described as the worldwide leader in PV inverter manufacturing, offering inverters suited to systems from single residences to large commercial installations. High efficiency and dependable data communication for system monitoring are central to the product range.

Sunny Boy
Sunny Central
Sunny Island
Sunny Beam
Sunny WebBox
Sunny Portal

See the full product overview →

Recognition for Quality

Stiftung Warentest

SMA products have been recognized as test winners at the German Product Standards Institute's Stiftung Warentest, a certification tied to Germany's most important quality seal.

Manufacturing Standard

Key manufacturing steps are completed in-house in Germany, supporting SMA's stated aim of top-quality products at competitive prices.

Company Motto

"Let's be realistic and attempt the impossible!" — the guiding motto behind SMA's approach to inverter development since 1981.

What the Portal Covers

Average annual energy exposure across the United States ranges from roughly 950 to 2,150 kWh/m², making solar power a viable option in most regions of the country. See the Energy Source and FAQ pages for details.

Questions About Solar Technology?

Use the contact form on the Solar is Future portal to submit questions or comments about photovoltaics, SMA products, or installation topics. Data submitted is used only to process your request.

SMA America, LLC
6020 West Oaks Blvd, Rocklin, CA 95765, U.S.A.
Tel. +1 916 625 0870  ·  Fax +1 916 0871
Email: info@solar-is-future.com

Go to Contact Page
Bright blue sky with white clouds and a warm sun flare over an open empty background, uplifting and airy mood

Hot spot heating in solar panels: causes and prevention

A hot spot in a photovoltaic module is a localised area where abnormal electrical resistance or current flow converts energy into heat. It often develops when shaded, soiled, cracked or mismatched cells are connected in series with cells producing more current. The affected patch can become much hotter than the surrounding glass while the rest of the module continues generating electricity.

The term does not always indicate a visibly damaged panel. Leaves, dust, bird droppings and partial shade can create the conditions, while a defective bypass diode, solder ribbon or cell connection may allow heating to continue after the obstruction is removed. Effective troubleshooting therefore separates temporary environmental causes from permanent electrical faults.

Australian rooftop systems face high irradiance, elevated ambient temperatures and substantial daily temperature changes. A small hot spot that goes unnoticed can contribute to delamination, damaged insulation or an arc fault. Early detection, sound string design and competent installation can prevent most avoidable cases.

How hot spots form in photovoltaic modules

Most cells within a module are connected in series, so each must carry the same current. If one cell becomes shaded or its output falls, stronger neighbouring cells can force current through it in reverse bias. Electrical energy is then dissipated locally as heat rather than collected as useful power. The effect often appears as a narrow band or small patch across several cells.

Each module normally includes bypass diodes designed to protect its internal substrings. Under an extreme mismatch, a diode may divert current around part of the module, but it cannot eliminate every shading or cell-level problem. Hot spots can also occur before a diode activates, particularly where a single cell has a crack, poor contact or manufacturing defect.

Persistent heating accelerates material degradation. Heat can weaken solder joints, crack cells, distort encapsulants and damage insulation around conductors. A minor mismatch may remain harmless for months, yet become serious once summer temperatures or electrical loading increases.

Australian conditions that raise the risk

Darwin experiences intense sunlight, high humidity and extremely high rooftop temperatures, making ventilation and sound electrical connections especially important. Alice Springs and inland South Australia can experience very hot days followed by cold nights, repeatedly cycling the modules and their mounting hardware. Temperature alone does not create a hot spot, but thermal cycling can make existing cell and ribbon weaknesses more likely to fail.

Shade is a common issue in Sydney’s leafy suburbs, where trees, chimneys and rooftop extensions cast moving shadows across arrays. Brisbane can also receive heavy seasonal rain that leaves dirt, mould or debris on modules. These conditions create unequal cell performance even when the obstruction covers only a small part of a panel.

Australian buyers often use the informal word “panels” for solar modules, while the local market includes everything from discount installations to specialist systems. That choice makes due diligence important: ask for a Clean Energy Council-accredited designer or installer, relevant product warranties and compliance with installation standards such as AS/NZS 5033 and AS/NZS 5131. Cheap modules are not the only concern, as hurried installation and poor string planning can create faults in otherwise capable equipment.

Signs and diagnosis of thermal damage

Visible clues include a persistent warm area, burnt-looking spots, yellowing around cell edges, cracked glass or a scorched junction box. A hotspot may also appear as a diagonal or horizontal band aligned with the module’s cell layout. These patterns can help distinguish shading or soiling from an electrical fault, although visual inspection alone is not conclusive.

A thermal camera provides a much clearer comparison during stable sunlight. An experienced technician can inspect the array, compare modules with similar orientation and identify abnormal temperature differences. Users should avoid climbing onto a hot roof, opening junction boxes or disconnecting live connectors, as the fault may involve stored energy or damaged insulation.

These observations help narrow the likely cause and identify a safe first response:

Observation Likely explanation Sensible first response
Warm area beneath foliage or dirt Shade or soiling reduces cell output Clean the surface and reassess after the obstruction is removed
Small hot patch aligned with a cell Cracked cell or weak interconnect Isolate the string and arrange electrical testing
Hot junction box or visible burn mark Diode, connector or insulation fault De-energise the affected circuit and call a qualified technician
One module warmer than adjacent modules Electrical mismatch or poor connection Compare operating temperatures and inspect the string
Warm areas appearing after rain Moisture ingress or degraded insulation Isolate the circuit and request an insulation test

Electrical testing should establish whether the fault lies in the module, its connectors, the cabling or the inverter. Replacing an affected module without investigating string design may leave the underlying mismatch in place, while repeatedly cleaning a permanently damaged module will not remove an internal fault.

Module design and component quality

Modern modules reduce electrical stress through larger cell areas, finer conductors, improved cell sorting and designs such as half-cut cells. These features can improve shade tolerance and lower operating current, but no panel design makes every hot spot impossible. Traceable manufacturing, robust bypass diodes and clear warranty terms remain important indicators of overall quality.

When comparing polycrystalline versus monocrystalline panels, buyers should consider temperature performance, efficiency, mechanical strength, warranty and installation suitability alongside cell technology. A premium panel paired with careless installation can still overheat, while a suitable module installed with precise string design and secure connections can perform reliably.

The number and placement of bypass diodes, connector design and internal wire dimensions also influence fault behaviour. Some systems use module-level power electronics such as optimisers or microinverters to manage shading and mismatch at module or panel level. These devices can improve energy yield and make faults easier to monitor, but they do not replace correct module selection, cable sizing or competent electrical work.

Installation practices that prevent thermal faults

Mechanical installation directly affects the cells and their connections. Clamps must sit in the manufacturer’s permitted zones, fasteners must be tightened to specification and rails must remain aligned without twisting the module frame. Walking across panels, forcing connectors or mounting hardware into positions that stress the laminate can create invisible microcracks that appear later as hot spots.

String design should account for module orientation, shading, current ratings and the electrical characteristics of every component. Series-connected modules with different orientations or output levels create current mismatch, while undersized DC cables can add heat at connections. Protective devices, isolation methods and inverter settings must be coordinated under Australian wiring rules and manufacturer instructions.

Reputable installers also test connections, verify polarity and measure string operating current before the system is commissioned. Documentation should identify module and inverter models, string layouts and any shading assumptions. Those records make it much easier to determine whether a later temperature anomaly is caused by site conditions, a changed surrounding environment or an emerging hardware fault.

A field response and maintenance routine

Consistent monitoring and a clear maintenance schedule reduce the chance that a developing defect remains hidden:

  • Survey the roof for new shade from trees, buildings, antennas or growing vegetation.
  • Check modules for dirt, debris, cracks, staining and damaged junction boxes.
  • Compare temperatures across modules with similar orientation during stable sunlight.
  • Have string currents, connections and insulation resistance tested periodically.
  • Keep installation records, warranties and monitoring data in one accessible place.
  • Replace damaged modules or connectors only after identifying the underlying cause.
  • Arrange professional inspection when a warm area persists or repeatedly reappears.

Persistent heating, a burnt smell, smoke or visible damage around a junction box should be treated as an urgent fault. Do not climb onto the roof or open the equipment. Switch off the array if it can be done safely from the accessible isolator, keep people away and contact the installer or a licensed electrician. If there is smoke or fire, call emergency services first.

For product compatibility advice or help assessing a suspected module fault, contact SMA’s solar specialists.