Know-How Portal from SMA Solar Technology AG — Photovoltaics, Solar Energy & Solar Technology
SMA America, LLC  ·  Tel. +1 916 625 0870
Photovoltaic Technology Overview
Overhead flat-lay of solar panel cells arranged in a neat grid, deep blue tones with clean charcoal borders, calm and technical mood

Solar energy sources, inverter technology, and installation know-how from SMA Solar Technology AG

Solar is Future gathers practical information on solar energy sources, photovoltaic technology, installation design, investment considerations, and recycling — built around the products and manufacturing experience of SMA Solar Technology AG, founded in 1981 in Niestetal, Germany.

Products Built on Inverter Leadership

SMA is described as the worldwide leader in PV inverter manufacturing, offering inverters suited to systems from single residences to large commercial installations. High efficiency and dependable data communication for system monitoring are central to the product range.

Sunny Boy
Sunny Central
Sunny Island
Sunny Beam
Sunny WebBox
Sunny Portal

See the full product overview →

Recognition for Quality

Stiftung Warentest

SMA products have been recognized as test winners at the German Product Standards Institute's Stiftung Warentest, a certification tied to Germany's most important quality seal.

Manufacturing Standard

Key manufacturing steps are completed in-house in Germany, supporting SMA's stated aim of top-quality products at competitive prices.

Company Motto

"Let's be realistic and attempt the impossible!" — the guiding motto behind SMA's approach to inverter development since 1981.

What the Portal Covers

Average annual energy exposure across the United States ranges from roughly 950 to 2,150 kWh/m², making solar power a viable option in most regions of the country. See the Energy Source and FAQ pages for details.

Questions About Solar Technology?

Use the contact form on the Solar is Future portal to submit questions or comments about photovoltaics, SMA products, or installation topics. Data submitted is used only to process your request.

SMA America, LLC
6020 West Oaks Blvd, Rocklin, CA 95765, U.S.A.
Tel. +1 916 625 0870  ·  Fax +1 916 0871
Email: info@solar-is-future.com

Go to Contact Page
Bright blue sky with white clouds and a warm sun flare over an open empty background, uplifting and airy mood

Solar Combined With Natural Gas Generators For Backup Power

Solar power can reduce electricity costs and improve energy independence, while a natural gas generator can provide dependable backup when batteries are depleted or sunlight is unavailable. Combining these technologies creates a hybrid energy system that balances clean daytime generation with dispatchable power for longer outages.

The arrangement suits homes, farms, small businesses and critical facilities that cannot rely solely on the grid. In Australia, where bushfires, severe storms, heatwaves and remote locations can interrupt supply, a coordinated solar and gas backup system can keep essential circuits operating without running a generator continuously.

Why Pair Solar With A Gas Generator

Solar panels produce electricity whenever sunlight is available, but their output changes with clouds, shading and the seasons. A battery can manage short interruptions and evening demand, yet a prolonged outage may require more stored energy than is practical or affordable. A gas generator provides a reserve that can run for many hours if fuel is available.

Natural gas generators generally produce fewer particulate emissions than diesel units and can be suitable where a mains gas connection already exists. Properties without pipeline access may use LPG cylinders or bulk tanks, although storage, delivery and regulator requirements need to be assessed carefully.

The generator does not need to supply every appliance in the building. A properly designed system separates essential loads such as refrigeration, communications, pumps, medical equipment and selected lighting from high-demand circuits. Solar and battery power can cover much of the daily load, with the generator starting only when required.

How The Hybrid System Operates

A hybrid inverter coordinates the solar array, battery, grid connection and generator. During normal operation, solar energy can serve household or commercial loads, charge the battery and export surplus electricity where the network allows it. If the grid fails, the inverter isolates the site and establishes a stable local supply for backed-up circuits.

The battery usually responds first to a short outage. It can provide rapid, quiet power while the controller checks whether solar production is sufficient. If the battery state of charge falls below a configured threshold, or if demand remains high for a set period, an automatic start signal is sent to the gas generator.

Generator compatibility is important. Many conventional generators are designed to run at a steady output, while solar inverters may need to curtail photovoltaic production when demand is low. The control system must prevent reverse power flow, excessive cycling and unstable frequency changes. Some systems use generator-ready inverters with dedicated start-stop contacts and programmable operating limits.

During daylight, the generator may run alongside solar power, although the controls should prevent the combined output from exceeding the site’s load or battery charging capacity. Generator minimum-load requirements also matter: operating a large machine at very low output can waste fuel and cause maintenance problems.

Designing For Australian Conditions

Australian system design varies greatly between a suburban property in Melbourne, a cattle station near Longreach and a coastal business in Cairns. A grid-connected home may need only a modest backup circuit, whereas an off-grid property may require a larger battery, generator and solar array to manage pumps, refrigeration and workshop equipment.

Heat is a significant consideration. In western Sydney, Adelaide and inland Queensland, high ambient temperatures can reduce battery and inverter performance and increase cooling demand. Equipment should be rated for the installation environment, mounted with adequate ventilation and protected from direct heat where possible.

Bushfire zones require attention to access, vegetation, emergency shutdown procedures and the location of fuel storage. Cyclone-prone areas around Darwin and northern Queensland need mounting structures, cabling and enclosures selected for local wind conditions. Coastal sites should also account for salt exposure and corrosion.

Australian electricity networks have their own connection rules, export limits and requirements for embedded generation. Accredited installers can check the relevant distribution network service provider requirements and ensure that the system’s islanding protection, metering and generator controls are accepted before commissioning.

Choosing The Right Generator And Inverter

Generator capacity should be based on essential loads, starting currents and the battery charging requirement rather than the total possible load of the property. Motors used in bore pumps, air conditioners and refrigeration can draw several times their normal running current when they start. A load assessment should identify which devices may operate together.

A generator that is too small may trip repeatedly or fail to start large motors. One that is too large can run inefficiently, cost more to install and impose a higher minimum load on the hybrid system. Natural gas supply pressure, pipe sizing and the capacity of the meter must be verified, especially when other gas appliances operate at the same time.

The inverter must support the intended operating mode. Important features include generator start control, frequency and voltage tolerance, black-start capability, battery charging limits and the ability to reduce solar output when the generator is running. Communication between the inverter, battery management system and generator controller is central to stable performance.

A system designer may also consider whether the solar array is DC-coupled or AC-coupled. DC-coupled systems can send solar energy directly through the hybrid inverter to the battery, while AC-coupled systems may offer flexibility when adding solar to an existing battery or generator installation.

System arrangement Main strength Key limitation Suitable application
Solar, battery and natural gas generator Covers short and extended outages with reduced fuel use More complex controls and installation Homes, farms and small businesses needing resilient backup
Solar and battery only Quiet operation and low routine maintenance Limited duration during extended cloudy weather Grid-connected sites with moderate backup needs
Natural gas generator only Long runtime while fuel is available Higher operating noise, fuel use and emissions Standby power where solar or batteries are impractical
Grid-connected solar without backup Lower electricity bills and daytime generation Does not operate during a grid outage Properties seeking energy savings rather than resilience

Costs, Fuel And Emissions

The initial cost includes solar panels, a hybrid inverter, batteries, generator equipment, changeover or isolation hardware, cabling, switchboard work and commissioning. A gas connection upgrade or LPG storage installation can add substantially to the project. Comparing the cost of backing up only essential circuits with the cost of backing up the whole property often reveals a more practical design.

Running costs depend on generator efficiency, gas prices, maintenance intervals and how frequently the unit starts. Solar energy can reduce generator runtime, particularly when the battery is charged during the day. A control strategy that starts the generator only at a useful load level may improve fuel efficiency and reduce unnecessary wear.

Natural gas is a fossil fuel, so a gas generator does not provide emissions-free backup. Its environmental performance should be compared with the local grid mix, generator efficiency, battery manufacturing impacts and the expected operating hours. For a system that runs only during outages or occasional battery support, fuel consumption may be modest; an off-grid property with regular generator use requires a more detailed lifecycle assessment.

Where floating solar is considered for reservoirs or industrial water sites, buoyancy, anchoring and maintenance access become additional design issues. A reference such as this pontoon multiplier may be relevant when reviewing the engineering principles behind floating structures, though the complete energy system still needs site-specific assessment.

Installation, Controls And Safety

Installation should be completed by appropriately licensed electrical and gas professionals. The system needs clear isolation points so technicians can safely work on the solar array, battery, inverter, generator and gas supply. Labelling should show the presence of multiple energy sources, including circuits that may remain energised during a grid outage.

The gas installation requires suitable ventilation, exhaust routing, clearances from windows and doors, and protection from vehicle impact or flooding. Carbon monoxide is a serious hazard, so generators must not operate in garages, enclosed plant rooms or areas where exhaust gases can enter occupied spaces.

Commissioning should test several operating conditions: grid failure, generator start, battery depletion, solar curtailment, restoration of the grid and generator shutdown. Measurements of voltage, frequency, current, power quality and transfer times help confirm that the controls behave as intended. Specialist measurement equipment can support accurate testing where suitable for the commissioning task.

The owner should receive a clear operating guide covering fuel isolation, emergency shutdown, warning indicators and restart procedures. Battery systems also need attention to fire safety, temperature limits, clearances and access for inspection. Local standards and fire authority requirements should be checked before equipment is ordered.

Keeping Performance Reliable

A hybrid backup system is an asset that needs routine care. Solar panels should be inspected for damage, heavy soiling and vegetation shading, while battery and inverter alerts should be reviewed through the available monitoring platform. Generator servicing commonly includes oil and filter changes, spark plug or ignition checks, coolant inspection where applicable, and testing of the automatic start function.

The generator should be exercised periodically under an appropriate load rather than left unused for years. A scheduled test can reveal weak batteries, fuel supply restrictions, failed control wiring or transfer-switch problems before an actual blackout occurs. Test records are useful for commercial sites with business continuity obligations.

Energy priorities may change over time. A new heat pump, bore pump, electric vehicle or refrigeration unit can alter the original load profile. Monitoring real consumption and reviewing the essential-load board helps determine whether the battery, inverter or generator still matches the site’s needs.

For Australian households and businesses, the most effective arrangement is usually a coordinated system rather than a collection of independent devices. Solar supplies low-cost daytime energy, the battery handles fast and short-duration changes, and the gas generator provides longer-duration support when weather or outage conditions demand it. Speak with an accredited installer to model your load profile, fuel availability, local network rules and backup priorities before selecting equipment.