Know-How Portal from SMA Solar Technology AG — Photovoltaics, Solar Energy & Solar Technology
SMA America, LLC  ·  Tel. +1 916 625 0870
Photovoltaic Technology Overview
Overhead flat-lay of solar panel cells arranged in a neat grid, deep blue tones with clean charcoal borders, calm and technical mood

Solar energy sources, inverter technology, and installation know-how from SMA Solar Technology AG

Solar is Future gathers practical information on solar energy sources, photovoltaic technology, installation design, investment considerations, and recycling — built around the products and manufacturing experience of SMA Solar Technology AG, founded in 1981 in Niestetal, Germany.

Products Built on Inverter Leadership

SMA is described as the worldwide leader in PV inverter manufacturing, offering inverters suited to systems from single residences to large commercial installations. High efficiency and dependable data communication for system monitoring are central to the product range.

Sunny Boy
Sunny Central
Sunny Island
Sunny Beam
Sunny WebBox
Sunny Portal

See the full product overview →

Recognition for Quality

Stiftung Warentest

SMA products have been recognized as test winners at the German Product Standards Institute's Stiftung Warentest, a certification tied to Germany's most important quality seal.

Manufacturing Standard

Key manufacturing steps are completed in-house in Germany, supporting SMA's stated aim of top-quality products at competitive prices.

Company Motto

"Let's be realistic and attempt the impossible!" — the guiding motto behind SMA's approach to inverter development since 1981.

What the Portal Covers

Average annual energy exposure across the United States ranges from roughly 950 to 2,150 kWh/m², making solar power a viable option in most regions of the country. See the Energy Source and FAQ pages for details.

Questions About Solar Technology?

Use the contact form on the Solar is Future portal to submit questions or comments about photovoltaics, SMA products, or installation topics. Data submitted is used only to process your request.

SMA America, LLC
6020 West Oaks Blvd, Rocklin, CA 95765, U.S.A.
Tel. +1 916 625 0870  ·  Fax +1 916 0871
Email: info@solar-is-future.com

Go to Contact Page
Bright blue sky with white clouds and a warm sun flare over an open empty background, uplifting and airy mood

Grounding and bonding in solar PV systems: safety essentials

Australia now has more than four million rooftop solar installations, and thousands of new systems go live every week from Cairns to Hobart. Alongside that growth comes a quiet but critical responsibility: making sure every panel, rail, inverter and cable is properly earthed and bonded. Failures in this part of a PV system can lead to electric shock, fires, equipment damage from lightning strikes and even voided warranties.

Grounding and bonding are sometimes used as if they were the same thing, yet they address different problems. Earthing provides a safe path for fault currents to dissipate into the general mass of earth, while bonding ties metallic parts together so they remain at the same potential. Both work together in a photovoltaic array to keep people, property and the inverter itself safe, and both are tightly regulated under Australian wiring rules.

Distinguishing earthing from equipotential bonding

Earthing, often called grounding, connects the non-current-carrying metalwork of a PV array to the earth electrode at the property. Its purpose is to provide a low-impedance route for fault currents and to stabilise voltages relative to ground. Bonding, by contrast, joins exposed conductive parts such as module frames, rails, combiner enclosures and inverter chassis so that no dangerous voltage difference can develop between them.

In Australia the distinction matters because the grid is referenced through the Multiple Earth Neutral scheme. Because the neutral conductor is earthed many times along the distribution network, the voltage between a rooftop array and a metal water pipe in the same house already sits close to zero in healthy operation. Bonding simply guarantees that corrosion, loose lugs or a damaged cable cannot turn that well-behaved zero into a live surface.

Think of earthing as the main road out of the home and bonding as the footpaths that keep every surface at the same level. People use the footpaths most of the day, but the road is what saves them if something fails. Both belong to the same safe-electrical system, planned by installer crews from Perth to Brisbane at the design stage of every job.

Australian standards that apply to PV earthing

The two documents any solar electrician Down Under needs at hand are AS/NZS 5033 and AS/NZS 3000, often called the Wiring Rules. AS/NZS 5033 covers photovoltaic arrays specifically, including earthing arrangements for module frames, mounting rails and array junction boxes. AS/NZS 3000 sets the broader rules that any installed equipment, including the inverter and switchboard, must follow.

Together they require that all exposed metal of a PV system that could otherwise rise to a hazardous voltage must be earthed, and that the earthing and equipotential bonding conductors be sized to carry the maximum fault current from the DC and AC sides. In high-rainfall coastal suburbs around Sydney and the Gold Coast, installers also reference AS/NZS 1768 for lightning protection guidance.

A common misunderstanding is that floating or ungrounded arrays are simpler and safer. Modern transformerless inverters do need careful handling because the DC circuit is no longer galvanically separated from the grid, yet skipping earthing is not an option. The standards assume a grounded or equivalently protected arrangement, which is also a focus of the Clean Energy Council accreditation course used by Australian installers.

Earthing module frames, rails and mounting hardware

Most crystalline-silicon modules ship with an earthing point, usually a hole or stud marked with the protective earth symbol. The conductor used must be copper, tinned copper or another material suited to local corrosion conditions. In seaside locations from Fremantle to Coffs Harbour, tinned conductors and stainless-steel fixings are considered best practice because salt-laden air eats copper in just a few seasons.

Mounting rails are usually aluminium, which is conductive but forms a non-conductive oxide layer over time. Dedicated earthing washers, WEEB clips or equivalent stainless-steel bite-through washers are used to penetrate that layer and create a lasting bond between the rail and each module frame. Skipping this step is one of the most frequent defects found during installation audits, partly because the joint still looks tight to the eye.

When the array sits on a structure rather than a roof, the conversation changes. Ground-mounted systems use longer cable runs, extra junction boxes and sometimes additional driven earth rods. A practical comparison of ground-mount versus roof-mount systems shows how the earthing layout extends across a wider footprint, with knock-on effects for surge protection and inspection access.

Equipotential bonding across array, inverter and switchboard

Once the frames and rails are tied back to a local earth point, the inverter needs to be brought into the same equipotential zone. The earth conductor of the inverter's AC output cable typically connects to the MEN link inside the main switchboard, while the DC side connects to the array's earthing arrangement. This two-sided bond ensures that even if a fault develops on DC cables in the roof cavity, the inverter chassis and any nearby metal plumbing stay at the same potential.

In practice this means a six-millimetre earth conductor running from the inverter to the switchboard's earth bar, plus a second conductor bonding the rooftop array frame back to the house's general earth. Metal water pipes, gas pipes or hot-water service hosing that pass near the array should also be checked, because induced voltages from switching events can otherwise find an unintended path.

Residual current devices add a layer of protection, but they rely on the bonding being correct in the first place. Without solid equipotential bonding, even a 30 mA RCD may not disconnect quickly enough to prevent harm from a parallel earth path through a person. Installers servicing suburbs with older switchboards, particularly in inner Melbourne and parts of Adelaide, often upgrade both the consumer mains earth and the PV earthing at the same time.

Earth electrodes, MEN behaviour and resistance targets

Australia's earthing rules rely on the Multiple Earth Neutral concept, in which the neutral conductor is earthed at the distribution transformer and frequently at intermediate points along the street. At a residential property a driven earth rod, an earth plate or a reinforcing bar in the slab becomes the local electrode, and its resistance must be low enough for fault currents to operate protection devices quickly.

AS/NZS 3000 suggests an earth electrode resistance below about 10 ohms for typical installations. In the sandy soils along parts of the Western Australian coast or in the red earth of regional Queensland, getting below 10 ohms can require additional electrodes spaced at least their length apart. Soil moisture matters too, so installers normally schedule testing after a soaking rain rather than during a dry spell.

A driven electrode only does its job if the connection head, the conductor and its protective conduit remain intact over decades. Many electricians now use gel-filled earth pit covers and label them clearly in line with the local distributor's requirements, so future workers do not chop through the cable while landscaping. These practices also satisfy the documentation that inspectors increasingly check as part of the solar installation paperwork.

Lightning and surge protection for rooftop and ground arrays

Australia sits in a region where summer thunderstorms regularly push cloud-to-ground lightning across the continent, so surge protection has become a standard talking point in PV design. A direct strike on a rooftop array is rare, but induced transients from nearby strikes can easily exceed the insulation rating of an inverter's input stage. Type 2 surge protective devices, installed at the DC isolators and at the AC switchboard, are now a routine recommendation.

Bonding needs to keep up with this protection. A surge device only works when its earth connection is short, straight and continuous. Excess cable length, sharp bends or shared paths with signal cables all degrade the device's ability to clamp the transient, so installers plan the SPD location and the bonding conductor early, rather than leaving them to the last minutes on site.

For properties in high-exposure areas such as the ranges west of Cairns, the foothills outside Canberra or the wide-open plains around Dubbo, a full lightning protection system with air terminals, down-conductors and a dedicated earth ring may be warranted. Even there, the PV array must integrate with the structure's protection so that fault currents from a strike do not pass through the home's switchboard in search of a path.

Practical recommendations for installers and homeowners

  • Always size the PV earthing conductor to handle the highest possible fault current from both the DC and AC sides, then add a margin for surge events.
  • Use tinned copper conductors and stainless fixings on arrays within about 10 km of a salt coastline, and re-torque every earthing lug during scheduled maintenance.
  • Test the earth electrode resistance at first commissioning and again after the first major storm or dry spell, recording both the reading and the soil conditions on the day.
  • Place surge protective devices as close as practical to the inverter's DC input and AC output, with the shortest possible bonding conductors back to the main earth bar.
  • Label every earthing point, bonding conductor and SPD at both ends so future electricians, roofers and HVAC technicians can see what must not be disconnected accidentally.

Good earthing and bonding are the quiet backbone of a reliable solar installation, and almost every warranty claim that comes back to the inverter manufacturer traces to a neglected connection somewhere in the array. Homeowners who ask their installer to walk them through the earth arrangement before the team leaves the roof gain real insight into how the system will behave in a fault, while installers who document the same details build a stronger reputation across the local industry. Understanding who designs and tests the inverter behind the array also helps, which is why many Australians look at the about-sma page when researching equipment that pairs with their carefully earthed array.